Process Control Instruments

PID Temperature Controller

Approx Price: Rs 6,500 / Piece(s) 
.4

TECHNICAL SPECIFICATION

Input type: (Either of below specifications can be used selectively in the one instrument)Thermocouple: K, S, R, E, J, N, T, B, WRe3-WRe25, WRe5-WRe26.

Resistance temperature detector: Cu50, Pt100Linear voltage: 05V, 15V, 01V, 0100mV, 020mV, 0~500mV etc.

Linear current (external precise shunt resist needed): 010mA,020mA, 420mA, etc.

Extended input (install I4 module in MIO) : 020mA, 420mA or two line transmitter.

Optional: apart from the above-mentioned Input type, an additional type can be provided upon request

(Graduation index is needed) Instrument Input rangeK(-501300℃), S(-501700℃), R(-501700℃), E(0800℃), J(01000℃), N(01300℃), T(-200~+350℃), B(200~1800℃)Cu50(-50+150℃), Pt100(-200+800℃)

Linear Input: -999030000 defined by user

Measurement accuracy : 0.3%FS ± 0.1℃ Resolution : 0.1℃ for K, E, T, N, J, Cu50, Pt100; 1℃ for S,R

Temperature shift : ≤0.015%FS /℃ (typical value is 80ppm/℃)

Sampling period : read A/D converter 8 times per second
 
Response time : ≤0.5s ( when digital filter parameter FILt=0)

Alarm function : High limit, low limit, deviation high limit and deviation low limit; providing the function of alarm blocking at the beginning of power on.

Control period : 0.24300.0 seconds selectable, and it should be integer times of 0.5 second.

Control mode:On-off control mode (dead band adjustable)

Standard PID with auto tuning AI PID with auto tuning, adopting artificial intelligence algorithm.

Output mode (modularized)

Relay output (NO+NC): 250VAC/1A or 30VDC/1ATRIAC no contact discrete output (NO or NC): 100240VAC/0.2A (continuous), 2A (20mS instantaneous, repeat period≥5s)

SSR Voltage output: 12VDC/30mA (used to drive SSR).

Thyristor zero crossing trigger output: Can trigger TRIAC of 5500A, a pair of inverse paralleled SCRs or SCR power module.Linear current output: 020mA, 420mA can scaling by user. (Output voltage : X3≥10.5V; X5≥7V maximum load resistor 500ohm, output precision 0.2%FS) Electromagnetic compatibility (EMC): ±4KV/5KHz according to IEC61000-4-4; 4KV according to

 2. DISPLAYS AND OPERATIONS2.1 Front Panel Description Upper display window: Displays PV, parameter code, etc. Lower display window: Displays SV, parameter value, or alarm message Setup key: For accessing parameter table and conforming parameter modification. Data shift key, start auto tuning Data decrease key, and also run switch Data increase key, and also stop key LED indicator: “MAN” led is non-applicable for AI-526 series. “RUN” led on, it mean AI-518P running program. MIO, OP1, OP2, AL1, AL2, AU1 and AU2 indicate I/O operation of the corresponding module. For example, when COMM led is lighting means that the instrument is communicating with computer.AI

PID Temperature Controller

Approx Price: Rs 6,500 / Piece(s) 
.4 Technical Specification

Input type: (Either of below specifications can be used selectively in the one instrument)

Thermocouple: K, S, R, E, J, N, T, B, WRe3-WRe25, WRe5-WRe26.

Resistance temperature detector: Cu50, Pt100

Linear voltage: 05V, 15V, 01V, 0100mV, 020mV, 0~500mV etc.

Linear current (external precise shunt resist needed): 010mA,020mA, 420mA, etc.Extended input (install I4 module in MIO) : 020mA, 420mA or two line transmitter.

Optional: apart from the above-mentioned Input type, an additional type can be provided upon request. (Graduation index is needed)

Instrument Input rangeK(-501300℃), S(-501700℃), R(-501700℃), E(0800℃), J(01000℃), N(01300℃), T(-200~+350℃), B(200~1800℃)Cu50(-50+150℃), Pt100(-200+800℃)

 Linear Input: -999030000 defined by user Measurement accuracy : 0.3%FS ± 0.1℃

Resolution : 0.1℃ for K, E, T, N, J, Cu50, Pt100; 1℃ for S,R

Temperature shift : ≤0.015%FS /℃ (typical value is 80ppm/℃)

Sampling period : read A/D converter 8 times per second

Response time : ≤0.5s ( when digital filter parameter FILt=0)

Alarm function : High limit, low limit, deviation high limit and deviation low limit; providing the function of alarm blocking at the beginning of power on.

Control period : 0.24300.0 seconds selectable, and it should be integer times of 0.5 second.

Control mode:On-off control mode (dead band adjustable)Standard PID with auto tuningAI PID with auto tuning, adopting artificial intelligence algorithm.

Output mode (modularized)

Relay output (NO+NC): 250VAC/1A or 30VDC/1ATRIAC no contact discrete output (NO or NC): 100240VAC/0.2A (continuous), 2A (20mS instantaneous, repeat period≥5s)SSR Voltage output: 12VDC/30mA (used to drive SSR).

Thyristor zero crossing trigger output: Can trigger TRIAC of 5500A, a pair of inverse paralleled SCRs or SCR power module.Linear current output: 020mA, 420mA can scaling by user. (Output voltage : X3≥10.5V; X5≥7V maximum load resistor 500ohm, output precision 0.2%FS) Electromagnetic compatibility (EMC): ±4KV/5KHz according to IEC61000-4-4; 4KV according to

 2. Display and Operation 2.1 Front Panel Description Upper display window: Displays PV, parameter code, etc. Lower display window: Displays SV, parameter value, or alarm message Setup key: For accessing parameter table and conforming parameter modification.

Data shift key, start auto tuning Data decrease key, and also run switch Data increase key, and also stop key LED indicator: “MAN” led is non-applicable for AI-526 series. “RUN” led on, it mean AI-518P running program. MIO, OP1, OP2, AL1, AL2, AU1 and AU2 indicate I/O operation of the corresponding module. For example, when COMM led is lighting means that the instrument is communicating with computer.AI

Temperature Indicator

Max Terma PID Controller

Capacitive Sensor

Blind Temperature Controller

Digital Temperature Controller

Digital Temperature Controller 2 SET POINT

Raytek Temperature Gun

Digital Event Counter

Push Button Stations

Temperature Controller

Temperature Controller

Digital Preset Counter

PID Temperature Controller

Looking for Process Control Instruments ?
© Electrical Controls & Switch Gears
Desktop Site Back to top